Ops Mgr SDK Tester Error

$
0
0

Anyone test QMX AS400 on the SCOM2012??

 

 

Below are the infos:

1. SCOM2012 installed on the management server

2. QMX(64bits) installed on non management server with agent installed and discovered succeful in SCOM.

 

- Performed Ops Mgr SDK Tester Connection but encountered error (refer to picture attached).

- Non windows proxy computer state show "NOT MONITORED"

 

3. Virtual agent can be start but show nothing in SCOM console. show error below in the logs

 

"<Hostname>In file /MOM/CommonRoutinesInsertPerformanceRecord.js, function InsertPerformanceRecordJS2SCOM error: Could not load file or assembly 'Microsoft.EnterpriseManagement.Core, Version=7.0.5000.0, Culture=neutral, PublicKeyToken=31bf3856ad364e35' or one of its dependencies. The system cannot find"


SCOM 2012 - QMX Netcool Connector

$
0
0

Hi Guys,

 

I am setting up my SCOM 2012 environment (moving from SCOM 2007 SP1 with fully working QMX and Netcool Connector)


So I have got the latest QMX BF and Netcool Extension, set it all up (64bit) and all the SCOM connectivity tests work fine.

I have configured everything the same for the Netcool Probe and everything seems to be fine.

 

However, every time the connector tries to collect an alert and forward it nothing gets sent.

The log shows errors, which I will include below, but it seems that it cannot look up the MIBs to me and is sending a default Minor alert from the standard Microsoft MIB

 

QMX log shows this, I have highlighted in Red the problem bit as far as I can see it.

 

>>>>>

22/05/2013 09:36:55:NetCoolConnector:WARNING: SCAN FOR ALERTS CREATED/UPDATED AT OR AFTER Tue May 21 23:20:29 UTC+0100 2013

22/05/2013 09:36:55:NetCoolConnector:

22/05/2013 09:36:55:NetCoolConnector:File MOM\CommonRoutinesConnector.js function GetNewAlertsFromMOM_ManagedCode(), informational: GetNewAlerts for SendSCOMAlertsToNetCool(73ed8efa-eaff-46c8-9e3a-0f31279974a8) succeeded.

22/05/2013 09:37:55:NetCoolConnector:File MOM\CommonRoutinesConnector.js function GetNewAlertsFromMOM_ManagedCode(), informational: GetNewAlerts for SendSCOMAlertsToNetCool(73ed8efa-eaff-46c8-9e3a-0f31279974a8) succeeded.

22/05/2013 09:37:55:NetCoolConnector:ProcessUpdatedAlertsReceivedFromMOM NOW ...

22/05/2013 09:37:55:NetCoolConnector:OBTAINED 1 UPDATED alerts from SCOM, checking to see if it/they should be forwarded

22/05/2013 09:37:55:NetCoolConnector:CONNECTOR FORWARDING <UPDATED> ALERT(l_strDescription) TO RECEIVER: BACKUP failed to complete the command BACKUP DATABASE OperationsManagerDW. Check the backup application log for detailed messages.

22/05/2013 09:37:55:NetCoolConnector:!!! UPDT: %comspec% /c THROWSNMPtrap -v 1  -c public ncpp-wb-p1  .1.3.6.1.4.1.17611 127.0.0.1 6 1 0  .1.3.6.1.4.1.17611.1.47.1.1 s "EventCollection" .1.3.6.1.4.1.17611.1.47.1.2 s "73ed8efa-eaff-46c8-9e3a-0f31279974a8" .1.3.6.1.4.1.17611.1.47.1.3 s "Pending" .1.3.6.1.4.1.17611.1.47.1.5 s "" .1.3.6.1.4.1.17611.1.47.1.6 s "" .1.3.6.1.4.1.17611.1.47.1.7 s "" .1.3.6.1.4.1.17611.1.47.1.8 s "" .1.3.6.1.4.1.17611.1.47.1.9 s "" .1.3.6.1.4.1.17611.1.47.1.10 s "" .1.3.6.1.4.1.17611.1.47.1.11 s "" .1.3.6.1.4.1.17611.1.47.1.12 s "CONNECTOR DEBUG TRACE POINT 3" .1.3.6.1.4.1.17611.1.47.1.13 s "ProcessedAsNewAlertAlready" .1.3.6.1.4.1.17611.1.47.1.14 s "Wed May 22 09:36:55 UTC+0100 2013" .1.3.6.1.4.1.17611.1.47.1.15 s "BACKUP failed to complete the command BACKUP DATABASE OperationsManagerDW. Check the backup application log for detailed messages." .1.3.6.1.4.1.17611.1.47.1.16 s "72da6636-70d4-4f1f-b549-abdbf4049298" .1.3.6.1.4.1.17611.1.47.1.17 s "False" .1.3.6.1.4.1.17611.1.47.1.18 s "22/05/2013 09:36:56" .1.3.6.1.4.1.17611.1.47.1.19 s "SYSTEMS\SRV-OMDAS" .1.3.6.1.4.1.17611.1.47.1.20 s "22/05/2013 09:36:56" .1.3.6.1.4.1.17611.1.47.1.21 s "" .1.3.6.1.4.1.17611.1.47.1.22 s "b68da2e3-ed66-e335-ac1b-606e7489476d" .1.3.6.1.4.1.17611.1.47.1.23 s "scom2012-mgmt" .1.3.6.1.4.1.17611.1.47.1.24 s "b87e82bc-1a85-4de3-330a-13133cf5f9c3" .1.3.6.1.4.1.17611.1.47.1.25 s "Warning" .1.3.6.1.4.1.17611.1.47.1.26 s "67ce2d1e-b44f-59db-61e0-5fa44c2cd14c" .1.3.6.1.4.1.17611.1.47.1.27 s "False" .1.3.6.1.4.1.17611.1.47.1.28 s "INST02" .1.3.6.1.4.1.17611.1.47.1.29 s "KN1-SQL-P6V02.systems.private" .1.3.6.1.4.1.17611.1.47.1.30 s "9598845b-f951-7b6f-9ea0-b7aa2663f4ed" .1.3.6.1.4.1.17611.1.47.1.31 s "Database Backup Failed To Complete" .1.3.6.1.4.1.17611.1.47.1.32 s "" .1.3.6.1.4.1.17611.1.47.1.33 s "Normal" .1.3.6.1.4.1.17611.1.47.1.34 s "9598845b-f951-7b6f-9ea0-b7aa2663f4ed" .1.3.6.1.4.1.17611.1.47.1.35 s "0" .1.3.6.1.4.1.17611.1.47.1.36 s "" .1.3.6.1.4.1.17611.1.47.1.37 s "Error" .1.3.6.1.4.1.17611.1.47.1.38 s "" .1.3.6.1.4.1.17611.1.47.1.39 s "21/05/2013 22:06:31" .1.3.6.1.4.1.17611.1.47.1.40 s "21/05/2013 22:06:31" .1.3.6.1.4.1.17611.1.47.1.41 s "21/05/2013 22:06:31" .1.3.6.1.4.1.17611.1.47.1.42 s "" .1.3.6.1.4.1.17611.1.47.1.43 s "INSERT" .1.3.6.1.4.1.17611.1.47.1.44 s " " .1.3.6.1.4.1.17611.1.47.1.45 s " " .1.3.6.1.4.1.17611.1.47.1.46 s " " .1.3.6.1.4.1.17611.1.47.1.47 s " " .1.3.6.1.4.1.17611.1.47.1.48 s "21/05/2013 22:20:29"

22/05/2013 09:37:55:NetCoolConnector:File MOM\CommonRoutinesConnector.js function UpdateAlertIntoMOM_ManagedCode(), UpdateAlerts for SendSCOMAlertsToNetCool (73ed8efa-eaff-46c8-9e3a-0f31279974a8) failed, error: [A]System.Collections.Generic.List`1[Microsoft.EnterpriseManagement.Monitoring.MonitoringAlertUpdateStatusIndigo] cannot be cast to [B]System.Collections.Generic.List`1[Microsoft.EnterpriseManagement.Monitoring.MonitoringAlertUpdateStatusIndigo]. Type A originates from 'mscorlib, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089' in the context 'LoadNeither' at location 'C:\Windows\assembly\GAC_64\mscorlib\2.0.0.0__b77a5c561934e089\mscorlib.dll'. Type B originates from 'mscorlib, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089' in the context 'LoadNeither' at location 'C:\Windows\assembly\GAC_64\mscorlib\2.0.0.0__b77a5c561934e089\mscorlib.dll'.

22/05/2013 09:37:55:NetCoolConnector:File MOM\CommonRoutinesConnector.js function UpdateAlertIntoMOM_ManagedCode(), UpdateAlerts for SendSCOMAlertsToNetCool (73ed8efa-eaff-46c8-9e3a-0f31279974a8) failed, error: [A]System.Collections.Generic.List`1[Microsoft.EnterpriseManagement.Monitoring.MonitoringAlertUpdateStatusIndigo] cannot be cast to [B]System.Collections.Generic.List`1[Microsoft.EnterpriseManagement.Monitoring.MonitoringAlertUpdateStatusIndigo]. Type A originates from 'mscorlib, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089' in the context 'LoadNeither' at location 'C:\Windows\assembly\GAC_64\mscorlib\2.0.0.0__b77a5c561934e089\mscorlib.dll'. Type B originates from 'mscorlib, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089' in the context 'LoadNeither' at location 'C:\Windows\assembly\GAC_64\mscorlib\2.0.0.0__b77a5c561934e089\mscorlib.dll'.

22/05/2013 09:37:55:NetCoolConnector:Diagnostics: g_numUPDATEDAlertsObtained = 6

22/05/2013 09:37:55:NetCoolConnector:UPDATED l_objDOM nulled out/released

22/05/2013 09:37:55:NetCoolConnector:ProcessNewAlertsReceivedFromMOM NOW ...

22/05/2013 09:37:55:NetCoolConnector:NEW l_objDOM nulled out/released

22/05/2013 09:37:55:NetCoolConnector:File MOM\CommonRoutinesConnector.js function SetBookmarkForConnectorThatSendsAlertsFromMOM_ManagedCode(), informational: SetBookMark forconnector SendSCOMAlertsToNetCool(73ed8efa-eaff-46c8-9e3a-0f31279974a8) for time 2013-05-22T00:20:31+06:00 succeeded.

22/05/2013 09:37:55:NetCoolConnector:

22/05/2013 09:37:55:NetCoolConnector:WARNING: SCAN FOR ALERTS CREATED/UPDATED AT OR AFTER Wed May 22 00:20:31 UTC+0100 2013

22/05/2013 09:37:55:NetCoolConnector:

22/05/2013 09:37:55:NetCoolConnector:File MOM\CommonRoutinesConnector.js function GetNewAlertsFromMOM_ManagedCode(), informational: GetNewAlerts for SendSCOMAlertsToNetCool(73ed8efa-eaff-46c8-9e3a-0f31279974a8) succeeded.

22/05/2013 09:38:55:NetCoolConnector:File MOM\CommonRoutinesConnector.js function GetNewAlertsFromMOM_ManagedCode(), informational: GetNewAlerts for SendSCOMAlertsToNetCool(73ed8efa-eaff-46c8-9e3a-0f31279974a8) succeeded.

22/05/2013 09:38:55:NetCoolConnector:ProcessUpdatedAlertsReceivedFromMOM NOW ...

22/05/2013 09:38:55:NetCoolConnector:OBTAINED 1 UPDATED alerts from SCOM, checking to see if it/they should be forwarded

22/05/2013 09:38:55:NetCoolConnector:CONNECTOR FORWARDING <UPDATED> ALERT(l_strDescription) TO RECEIVER: BACKUP failed to complete the command BACKUP DATABASE OperationsManagerDW. Check the backup application log for detailed messages.

22/05/2013 09:38:55:NetCoolConnector:!!! UPDT: %comspec% /c THROWSNMPtrap -v 1  -c public ncpp-wb-p1  .1.3.6.1.4.1.17611 127.0.0.1 6 1 0  .1.3.6.1.4.1.17611.1.47.1.1 s "EventCollection" .1.3.6.1.4.1.17611.1.47.1.2 s "73ed8efa-eaff-46c8-9e3a-0f31279974a8" .1.3.6.1.4.1.17611.1.47.1.3 s "Pending" .1.3.6.1.4.1.17611.1.47.1.5 s "" .1.3.6.1.4.1.17611.1.47.1.6 s "" .1.3.6.1.4.1.17611.1.47.1.7 s "" .1.3.6.1.4.1.17611.1.47.1.8 s "" .1.3.6.1.4.1.17611.1.47.1.9 s "" .1.3.6.1.4.1.17611.1.47.1.10 s "" .1.3.6.1.4.1.17611.1.47.1.11 s "" .1.3.6.1.4.1.17611.1.47.1.12 s "CONNECTOR DEBUG TRACE POINT 3" .1.3.6.1.4.1.17611.1.47.1.13 s "ProcessedAsNewAlertAlready" .1.3.6.1.4.1.17611.1.47.1.14 s "Wed May 22 09:37:55 UTC+0100 2013" .1.3.6.1.4.1.17611.1.47.1.15 s "BACKUP failed to complete the command BACKUP DATABASE OperationsManagerDW. Check the backup application log for detailed messages." .1.3.6.1.4.1.17611.1.47.1.16 s "72da6636-70d4-4f1f-b549-abdbf4049298" .1.3.6.1.4.1.17611.1.47.1.17 s "False" .1.3.6.1.4.1.17611.1.47.1.18 s "22/05/2013 09:37:56" .1.3.6.1.4.1.17611.1.47.1.19 s "SYSTEMS\SRV-OMDAS" .1.3.6.1.4.1.17611.1.47.1.20 s "22/05/2013 09:37:56" .1.3.6.1.4.1.17611.1.47.1.21 s "" .1.3.6.1.4.1.17611.1.47.1.22 s "b68da2e3-ed66-e335-ac1b-606e7489476d" .1.3.6.1.4.1.17611.1.47.1.23 s "scom2012-mgmt" .1.3.6.1.4.1.17611.1.47.1.24 s "b87e82bc-1a85-4de3-330a-13133cf5f9c3" .1.3.6.1.4.1.17611.1.47.1.25 s "Warning" .1.3.6.1.4.1.17611.1.47.1.26 s "67ce2d1e-b44f-59db-61e0-5fa44c2cd14c" .1.3.6.1.4.1.17611.1.47.1.27 s "False" .1.3.6.1.4.1.17611.1.47.1.28 s "INST02" .1.3.6.1.4.1.17611.1.47.1.29 s "KN1-SQL-P6V02.systems.private" .1.3.6.1.4.1.17611.1.47.1.30 s "9598845b-f951-7b6f-9ea0-b7aa2663f4ed" .1.3.6.1.4.1.17611.1.47.1.31 s "Database Backup Failed To Complete" .1.3.6.1.4.1.17611.1.47.1.32 s "" .1.3.6.1.4.1.17611.1.47.1.33 s "Normal" .1.3.6.1.4.1.17611.1.47.1.34 s "9598845b-f951-7b6f-9ea0-b7aa2663f4ed" .1.3.6.1.4.1.17611.1.47.1.35 s "0" .1.3.6.1.4.1.17611.1.47.1.36 s "" .1.3.6.1.4.1.17611.1.47.1.37 s "Error" .1.3.6.1.4.1.17611.1.47.1.38 s "" .1.3.6.1.4.1.17611.1.47.1.39 s "21/05/2013 22:06:31" .1.3.6.1.4.1.17611.1.47.1.40 s "21/05/2013 22:06:31" .1.3.6.1.4.1.17611.1.47.1.41 s "21/05/2013 22:06:31" .1.3.6.1.4.1.17611.1.47.1.42 s "" .1.3.6.1.4.1.17611.1.47.1.43 s "INSERT" .1.3.6.1.4.1.17611.1.47.1.44 s " " .1.3.6.1.4.1.17611.1.47.1.45 s " " .1.3.6.1.4.1.17611.1.47.1.46 s " " .1.3.6.1.4.1.17611.1.47.1.47 s " " .1.3.6.1.4.1.17611.1.47.1.48 s "21/05/2013 23:20:31"

22/05/2013 09:38:56:NetCoolConnector:File MOM\CommonRoutinesConnector.js function UpdateAlertIntoMOM_ManagedCode(), UpdateAlerts for SendSCOMAlertsToNetCool (73ed8efa-eaff-46c8-9e3a-0f31279974a8) failed, error: [A]System.Collections.Generic.List`1[Microsoft.EnterpriseManagement.Monitoring.MonitoringAlertUpdateStatusIndigo] cannot be cast to [B]System.Collections.Generic.List`1[Microsoft.EnterpriseManagement.Monitoring.MonitoringAlertUpdateStatusIndigo]. Type A originates from 'mscorlib, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089' in the context 'LoadNeither' at location 'C:\Windows\assembly\GAC_64\mscorlib\2.0.0.0__b77a5c561934e089\mscorlib.dll'. Type B originates from 'mscorlib, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089' in the context 'LoadNeither' at location 'C:\Windows\assembly\GAC_64\mscorlib\2.0.0.0__b77a5c561934e089\mscorlib.dll'.

22/05/2013 09:38:56:NetCoolConnector:File MOM\CommonRoutinesConnector.js function UpdateAlertIntoMOM_ManagedCode(), UpdateAlerts for SendSCOMAlertsToNetCool (73ed8efa-eaff-46c8-9e3a-0f31279974a8) failed, error: [A]System.Collections.Generic.List`1[Microsoft.EnterpriseManagement.Monitoring.MonitoringAlertUpdateStatusIndigo] cannot be cast to [B]System.Collections.Generic.List`1[Microsoft.EnterpriseManagement.Monitoring.MonitoringAlertUpdateStatusIndigo]. Type A originates from 'mscorlib, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089' in the context 'LoadNeither' at location 'C:\Windows\assembly\GAC_64\mscorlib\2.0.0.0__b77a5c561934e089\mscorlib.dll'. Type B originates from 'mscorlib, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089' in the context 'LoadNeither' at location 'C:\Windows\assembly\GAC_64\mscorlib\2.0.0.0__b77a5c561934e089\mscorlib.dll'.

22/05/2013 09:38:56:NetCoolConnector:Diagnostics: g_numUPDATEDAlertsObtained = 7

22/05/2013 09:38:56:NetCoolConnector:UPDATED l_objDOM nulled out/released

22/05/2013 09:38:56:NetCoolConnector:ProcessNewAlertsReceivedFromMOM NOW ...

22/05/2013 09:38:56:NetCoolConnector:NEW l_objDOM nulled out/released

22/05/2013 09:38:56:NetCoolConnector:File MOM\CommonRoutinesConnector.js function SetBookmarkForConnectorThatSendsAlertsFromMOM_ManagedCode(), informational: SetBookMark forconnector SendSCOMAlertsToNetCool(73ed8efa-eaff-46c8-9e3a-0f31279974a8) for time 2013-05-22T23:05:37+06:00 succeeded.

22/05/2013 09:38:56:NetCoolConnector:

>>>>

 

So is there something I have missed in the setup? I have gone through both config docs I can find, to be fair they are not the best as they still show old pics for the old Baseframework etc

 

Help?

 

SNMP traps not generating alerts

$
0
0

We have an EMC NS-20.  When I send test traps to the server that has the EXC software on it, the traps do show up in the log for the node, but no alert is generated in SCOM.

Here is the log entry:

2/18/2009 8:25:36 AM:OAT-NS20:SNMPTrap_UserExit: state=NORMAL returnCode=1
2/18/2009 8:25:36 AM:OAT-NS20: === Found in DB     === START TRAP
2/18/2009 8:25:36 AM:OAT-NS20: __SERVER = <null> of type WMI
2/18/2009 8:25:36 AM:OAT-NS20: __DERIVATION = SnmpExtendedNotification, __ExtrinsicEvent, __Event, __IndicationRelated, __SystemClass of type WMI
2/18/2009 8:25:36 AM:OAT-NS20: __NAMESPACE = <null> of type WMI
2/18/2009 8:25:36 AM:OAT-NS20: __PATH = <null> of type WMI
2/18/2009 8:25:36 AM:OAT-NS20: AgentAddress = 134.139.25.150 of type WMI
2/18/2009 8:25:36 AM:OAT-NS20: __CLASS = SnmpV1ExtendedNotification of type WMI
2/18/2009 8:25:36 AM:OAT-NS20: __GENUS = 2 of type WMI
2/18/2009 8:25:36 AM:OAT-NS20: AgentTransportAddress = 134.139.25.150 of type WMI
2/18/2009 8:25:36 AM:OAT-NS20: AgentTransportProtocol = IP of type WMI
2/18/2009 8:25:36 AM:OAT-NS20: Community = scompublic of type WMI
2/18/2009 8:25:36 AM:OAT-NS20: Identification = 1.3.6.1.4.1.1139.2.0.10 of type WMI
2/18/2009 8:25:36 AM:OAT-NS20: Identification2 = iso.3.6.1.4.1.1139.2.0.10 of type WMI
2/18/2009 8:25:36 AM:OAT-NS20: SECURITY_DESCRIPTOR = <null> of type WMI
2/18/2009 8:25:37 AM:OAT-NS20: TIME_CREATED = 128794479366760504 of type WMI
2/18/2009 8:25:37 AM:OAT-NS20: TimeStamp = 1580363857 of type WMI
2/18/2009 8:25:37 AM:OAT-NS20: __SUPERCLASS = SnmpExtendedNotification of type WMI
2/18/2009 8:25:37 AM:OAT-NS20: __DYNASTY = __SystemClass of type WMI
2/18/2009 8:25:37 AM:OAT-NS20: __RELPATH = <null> of type WMI
2/18/2009 8:25:37 AM:OAT-NS20: __PROPERTY_COUNT = 9 of type WMI
2/18/2009 8:25:37 AM:OAT-NS20:----------------------
2/18/2009 8:25:37 AM:OAT-NS20: 1.3.6.1.4.1.1139.2.1.1.2(iso.3.6.1.4.1.1139.2.1.1.2) = 0 of type INTEGER
2/18/2009 8:25:37 AM:OAT-NS20: 1.3.6.1.4.1.1139.2.1.1.3(iso.3.6.1.4.1.1139.2.1.1.3) = 2 of type INTEGER
2/18/2009 8:25:37 AM:OAT-NS20: 1.3.6.1.4.1.1139.2.1.1.4(iso.3.6.1.4.1.1139.2.1.1.4) = Feb 18 08:17:41 2009 LocalHardwareMonitor:2:0 User Generated Test Message  of type OCTET STRING
2/18/2009 8:25:37 AM:OAT-NS20: 1.3.6.1.3.1057.1(iso.3.6.1.3.1057.1) = 134.139.25.150 of type IpAddress
2/18/2009 8:25:37 AM:OAT-NS20: 1.3.6.1.6.3.1.1.4.3.0(iso.3.6.1.6.3.1.1.4.3.0) = 1.3.6.1.4.1.1139.2 of type OBJECT IDENTIFIER
2/18/2009 8:25:37 AM:OAT-NS20: 1.3.6.1.4.1.1139.2.1.1.1(iso.3.6.1.4.1.1139.2.1.1.1) = -117 of type INTEGER
2/18/2009 8:25:37 AM:OAT-NS20: ===================== END TRAP
2/18/2009 8:25:37 AM:OAT-NS20:

CWBCO1008 Unable to connect to server application returned 8403

$
0
0

Anyone can assit on this error?

 

 

E - CWBCO1008 - Unable to connect to server application Central Client, returned

8403

 

E - CWBCO1008 - Unable to connect to server application Network File, returned 8

403

 

E - CWBCO1008 - Unable to connect to server application Network Print, returned

8403

 

E - CWBCO1008 - Unable to connect to server application Data Access, returned 84

03

 

E - CWBCO1008 - Unable to connect to server application Data Queues, returned 84

03

 

E - CWBCO1008 - Unable to connect to server application Remote Command, returned

8403

 

E - CWBCO1008 - Unable to connect to server application Security, returned 8403

 

E - CWBCO1008 - Unable to connect to server application DDM, returned 8403

 

E - CWBCO1008 - Unable to connect to server application Telnet, returned 8403

 

E - CWBCO1016 - Connection verify to system <hostname> failed

Weblogic

$
0
0

Just installed the Weblogic extender and it does not seem to be communicating with SCOM.  I have added the community strings that the UNIX admins gave me am I missing steps?  There was documentation with the download from the Dell website.

Life Line Please, simple connection, big problem.

$
0
0
Here is the deal, help me fix this, I guarantee the purchase of more licenses, seriously.

Justin and I could not figure it out over the last two days, I spent all day today rebuilding the environment thinking I missed something....NOT

Code:
Base Framework:  4.0.0.509
HPUX Ext: v7.0.0.9
Oracle Ext: v7.0.0.11

Point:  it WAS working before the upgrade (now re-install).

The problem, after reinstallation (from the SCOM agent to the BASE Framework and extensions).  After a successful SDK connection test, we try a Oracle DB connection test and can NOT get by the following error:

Connect: ORA-12514: TNS:listener does not currently know of service requested in connect descriptor.

OK, so we go to the db server in question and run these commands.

1. lsnrctl services VendavoDTI    (the Instance/SID)
The command completed Successfully

2. sqlplus tesetuser@VendavoDTI
> Password:  testuser1
> SQL
Connection Good, Credentials Good.

3. SQL > show parameter service_names
service_names                    string                VendavoDTI.dti.com

4. sqlplus testuser/testuser1@VendavoDTI
Successful

5. From the Proxy Server, ping dtidbp20
Successful

The listener.log shows this from my connection attempt

11-NOV-2009 18:31:53 * (CONNECT_DATA=(SERVER=DEDICATED)(SERVICE_NAME=VendavoDTI)(CID=(PROGRAM=D:\Program?Files\eXc?Software\WMI?Providers\nonWindows\Virtual?Agent?Library\MOM\Oracle\OracleTestConnection.exe)(HOST=DTIFS02)(USER=sidscp01))) * (ADDRESS=(PROTOCOL=tcp)(HOST=161.16.238.58)(PORT=4583)) * establish * VendavoDTI * 12514
TNS-12514: TNS:listener does not currently know of service requested in connect descriptor

6. tnsping VendavoDTI    (executed on the database server)
OK (60msec)

I attached the tnsnames.ora to this post.

Please....please advise....

(vCenter) status changed from green to yellow

$
0
0
Hi,


I recieved a many these non-Windows Alerts. How can I disable this rule or monitor ? What this alert means ?

Alert: non-Windows Alert
Source: vcenter
Path: SCOM.xxx.xx
Last modified by: System
Last modified time: 29. 7. 2010 0:49:37
Alert description: VMWare8006: HostName=  TrapType=host ObjValue=alarm.HealthStatusChangedAlarm - Event: Status change (442675)
Summary: VCENTER.xxx.xx (vCenter) status changed from greento yellow
Date: 28. 7. 2010 22:49:27
User name: Health Service
Arguments:
    componentId =1E1F0B3D-8276-4ADF-9BAD-B44A80E8DE2E
    componentName =VCENTER.xxx.xx (vCenter)
    newStatus =yellow
    oldStatus =green

Thanks

Management pack for SCOM 2007 R2

$
0
0

Can some one please tell me how and where to download the following quest manamnegt packs . I know a  cost is involved but will like a train version first

 

APC - UPS Manangment pack for SCOM 2007 R2

 

MacAfee EPO Managmnet pack for SCOM 2007 R2

 

BES  Blackberry Managment pack for SCOM 2007 R2

 

 

Thnaks


Emergency : Search informix MP for SCOM 2007 R2

$
0
0
Hi all,

My company has implemented SCOM 2007 R2 and we want to know if Quest Software has a management pack for informix. We want to montor our database informix installed on a server AIX 5.3.

Can you tell me please if Quest has a connector to integrate the monitoring of informix database in SCOM 2007 R2 ? If yes, how does it works?

I need your help, it's an emergency!

Regards.

QMX management extensions reporting to 2 Ops Mgr Management Groups

$
0
0

Can a Quest Operations manager extension system be configured to communicate with two System Center Operations Manager management groups?

We currently use it to monitor non windows devices in SCOM 2007 R2, and would like to monitor to both the existing Ops Mgr system and a new SCOM 2012 system during a staged migration.

Can we install QMX and SCCM client on the same machine

$
0
0

Hello ,

 

We have QMX 4.0.5 installed with SCCM 2012. As sccm 2012 SP1 supports non windows clients, can sccm and QMX client can be installed on the same machine? Need to provide this input to management as they need to decide to go ahead with QMX or SCCM. We are aware of the client OS supported by SCCM and QMX.Please Help.

 

Also we have licensed version of QMX installed. How does QMX license work? Do we need to renew it after some years?

QMX v4 / SCCM 2012 / iPad Mgt Stopped Working

$
0
0

Hi,

 

I have had SCCM 2012 and QMXv4 extenstions working in my lab environment.  I was able to deploy profiles and applications to my iPad.  However, the environment has been switched off for the last 4 weeks.

 

After I started it up the environment again, using an iPad I tried to trust the device, this worked.  A Profile was available on the iPad. 

 

I tried the next option which was to enroll the device, however I get the following error...."The QMX MDM service is unable to handle your request at this time.  Please contact your administrator".

 

I have confirmed that the QMX server is able to contact my domain controller, Certificate Authority Server, and ConfigMgr Server.

 

After examining the Application event logs, I can see the following error.

 

Event 10, NetworkDeviceEnrrollmentService

The Network Device Enrollment Service cannot retrieve one of its required certificates (0x80070057).  The Parameter is incorrect.

 

I have done some checking on what this error means and how to resolve it, but I was wondering if anyone has seen this before, or to suggest a possible solution.

 

Thanks

 

Steve

Needs NaviCli?

$
0
0
EMC API VA? The port NaviCli does use? Does this VA needs NaviCli to be installed?

QMX CLI Auto Discovery Results for MacOSX & Collections issue

$
0
0

Hi Guys

 

I cant seem to view the collections for Non Windows Machines within the SCCM console. Do i need to create this manually??

 

Also the Auto discovery looks like the following is this corrrect?

 

Screen Shot 2012-04-10 at 15.01.06.png

 

Sorry im a Newbie to both SCCM and this tool.

 

Regards

 

Jamie

Framework 4.0.0.509 Performance Collection issue with SCOM

$
0
0
Gentleman, help !!!!

** Logistics **

Open Case Number: 774239

SCOM 2007 SP1  (Proxy IS enabled on QMX server, agent IS healthy in SCOM)

Base Framework: 4.0.0.509
Oracle Extension: 7.0.0.11
QMX Oracle MP: 7.0.0.2 (Size=92KB, Date=10-21-2009)  (from Oracle Extension)

eXcSoftware.nonWindows.Dynamic MP = 7.0.0.0    Date: 11/23/2009 2:01:27PM

Tools/Debug/OpsMgr Connectivity Tests = Good
Oracle DB Connection Test = Good

Alerts flowing across to SCOM  = Good
Performance data flowing across to SCOM = Good

The Problem:
When we enable through the config tool, MOM/OpsMgrGlobalVariables/g_boolWriteOpsMgrPerfMetricsToDWDB (throu the agent)

we get the following (2) errors repeatedly on our RMS(production) server:
** And our RMS CPU/Memory goes through the roof!
Event Type:             ErrorEvent Source:         OpsMgr SDK ServiceEvent Category:      NoneEvent ID:  26319Date:                        12/1/2009Time:                        5:05:43 PMUser:                       N/AComputer:                edcomp10Description:An exception was thrown while processing UpdateManagementPack for session id uuid:e8c66cbb-aebd-4474-8702-040b037cf085;id=13176. Exception Message: The creator of this fault did not specify a Reason. Full Exception: System.ServiceModel.FaultException`1[Microsoft.EnterpriseManagement.Common.ManagementPackException]: The creator of this fault did not specify a Reason. (Fault Detail is equal to : Database error. [MPInfra_p_ManagementPackInstall] failed with exception:Database error. [MPInfra_p_ManagementPackInstall] failed with exception:ManagementPack cannot be updated because eXcSoftware.nonWindows.nonWindowsObject.PerformanceRule.Template.Folder has been modified more recently.). For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp.   Event Type:             WarningEvent Source:         DataAccessLayerEvent Category:      NoneEvent ID:  33333Date:                        12/1/2009Time:                        5:05:43 PMUser:                       N/AComputer:                edcomp10Description:Data Access Layer rejected retry on SqlError: Request: MPInfra_p_ManagementPackInstall -- (ManagementPackXML=<ManagementPack xmlns:xsd="http://www.w3.org/2001/XMLSchema" xmlns:xsl="http://www.w3.org/1999/XSL/Transform" ContentReadable="t...), (ManagementPackXMLUpdateFragment=<ManagementPack xmlns:xsd="http://www.w3.org/2001/XMLSchema" xmlns:xsl="http://www.w3.org/1999/XSL/Transform" ContentReadable="t...), (RunTimeXML=<ManagementPack xmlns:xsd="http://www.w3.org/2001/XMLSchema" xmlns:xsl="http://www.w3.org/1999/XSL/Transform" ContentReadable="t...), (MPKeyToken=), (RETURN_VALUE=1) Class: 16 Number: 777980306 Message: ManagementPack cannot be updated because eXcSoftware.nonWindows.nonWindowsObject.PerformanceRule.Template.Folder has been modified more recently. For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp.


Ironically, writing the performance data TO the DW IS working, we check using this sql:

1. Log into your DW, start SQL Server Management Studio
2. Select your DW, select "new query"
3. In the query below, replace this value <edcdbd32> with a server that is monitored in your environment.

Run this query:

SELECT  DISTINCT ObjectName, CounterName,Cast(LEFT(Datetime,11)asdatetime)datetimeFROM         vManagedEntity INNERJOIN                      Perf.vPerfDaily ON vManagedEntity.ManagedEntityRowId = Perf.vPerfDaily.ManagedEntityRowId INNERJOIN                      vPerformanceRuleInstance ON                      Perf.vPerfDaily.PerformanceRuleInstanceRowId = vPerformanceRuleInstance.PerformanceRuleInstanceRowId INNERJOIN                      vPerformanceRule ON vPerformanceRuleInstance.RuleRowId = vPerformanceRule.RuleRowId  WHERE    (vManagedEntity.Fullname LIKE'%edcdbd32%') andDateTImeBETWEENGetdate()-90 andgetdate() --ORDER BY datetimeORDERBY Objectname, CounterName,datetime


It should return rows like this:  (what you are looking for is objectNames like the following):
SYS.V_SGASTAT
SYS.V_SGASTAT
SYS.V_SGASTAT
SYS.V_SHARED_POOL_RESERVED
SYS.V_SHARED_POOL_RESERVED
SYS.V_SHARED_POOL_RESERVED
SYS.V_SHARED_POOL_RESERVED
SYS.V_SHARED_SERVER_MONITOR
SYS.V_SHARED_SERVER_MONITOR
SYS.V_SYSSTAT
SYS.V_SYSSTAT
SYS.V_SYSSTAT

OK, so, I hate to cry WOLF, but I am really under the gun now, please advise, I have tried multiple things to resolve the issue, ironically, we did NOT see this in our development environment.  The difference between dev and prd is dev is R2 and prod is SCOM 2007 SP1, no other "real" difference I can put my finger on.

Any help would be very much appreciated.

Richard


PowerConnect counters in SCOM 2007 R2

$
0
0

I've implemented the QMX for Operations Manager and have my Dell PowerConnect servers put into the Administration Console, they are showing up in Operations Manager. 

I'm specifically looking for network utilization, CPU, and the basic vitals for all my PowerConnects.

In the Dell PowerConnect Performance SCOM view, I only get one counter for each PowerConnect.  This object: connectivity, counter:"LATENCY_SECONDS".  Is there a way to get any additional counters? i.e. CPU and utilization rates? 

It seems like a simple request, yet I'm having a hard time finding a product that can unify all of these stats (ideally in SCOM) without logging on to each PowerConnect's web GUI individually.

Thanks,
Jon

Monitor AS400 via port 992 instead of port 23

$
0
0

Is there anyway we can monitor customer AS400 using port 992 instead port 23 where port opening for it is not possible?

Quest QMX for non-Windows Version 4.0.0.519 with SCOM12 Agent?

$
0
0

Hello everybody!

 

Thanks in advance for your help!

 

Our environments (test and productive) are getting a SCOM 2012 migration. first the test environment of course

 

Here the Test Env. components:

 

SCOM 2007 R2

1 rms: OS Win 2008r2

1 mgmt. Server: OS Win2008 R2

1 QMX Server for monitoring of (MQSeries, VMWare and Websphere): OS Win2008 R2

QMX Product: Quest QMX for non-Windows

Version 4.0.0.519

1 SQL DB Cluster for all DBs

~50 SCOM Agents

 

now the situation:

The mgmt. Server has been already upgrade to 2012. Now the agents moved to pending management. so far so good!

and finally, here my question:

 

Does the monitoring of QMX still working after the update to the new SCOM12 Agent?

if not, wich steps should I do first?

 

Many Thanks for your help!

br

Dave

Unable to Register ISV Proxy

$
0
0

Hi all,

 

I am standing up a new SCCM site build and I am recieving the following error after running the SCCM connectivity tests

 

Unable to Register ISV Proxy: CSMSManagementPoint::SignHashHexEncode:CryptAcquireCertificatePrivateKey failed with error -2146885621: Cannot find the certificate and pricate key for decryption.

 

The certificate was exported and registered without error. QMX is installed on the same computer as SCCM.  I can see the certificate in the SCCM Console.

We are running SCCM2007 R3 with QMX base framework 4.0.6.67 on Server 2008R2

 

I compared my settings to my old machine and everything looks to be ok.  Any thoughts?

IBM Websphere MQ Series

$
0
0
Does the IBM Websphere MQ Series work with MQ Version 7?